Free Engineering Tool · NIST SP 811

Fire Protection Unit Converter

Unit conversions for the quantities fire protection engineers move between US and SI units every day: sprinkler K-factor, design density, flow, pressure and feet of water, heat release rate, heat flux, heat of combustion, RTI and more. Pick a quantity, enter a value and see it in every unit at once, with the basis of each factor.

  • Based on NIST SP 811
  • Free, runs in your browser; your inputs stay on your device
  • Screening tool, not reviewed or sealed by a licensed engineer
  • Last updated October 2026

Screening tool, not engineering advice. This calculator estimates results with simplified published methods. It has not been reviewed or sealed by a licensed engineer for your project, and DGA does not warrant that its results are accurate, complete or suitable for any use. Check every result independently and have the licensed professional responsible for your project review it before you rely on it. Use is subject to the Terms of Use.

Convert

Factors are exact by definition or taken from NIST Special Publication 811. Btu and calorie values use the International Table definitions.

Result

Metric (SI)
0
US customary
0
Conversion factor
0

Every Unit

UnitValueBasis
Keep these results

About This Tool

Each quantity converts through one base unit. A value is multiplied by its unit’s factor to reach the base and divided by the target unit’s factor to leave it, so every row in the table comes from the same number. Most factors are exact because they follow from exact definitions: 1 ft = 0.3048 m, 1 in. = 25.4 mm, 1 lb = 0.45359237 kg, 1 lbf = 4.4482216152605 N, 1 US gal = 3.785411784 L, 1 Btu (International Table) = 1,055.05585262 J and standard gravity 9.80665 m/s2. The few that rest on a physical property, such as the inch of water at 60 °F (248.84 Pa) and the US therm, use the values in NIST Special Publication 811 and are marked in the table.

Several conversions are specific to fire protection. A sprinkler K-factor in gpm/psi½ times 14.4163 gives L/min/bar½, because flow converts directly but pressure sits under a square root. A design density in gpm/ft2 times 40.746 gives mm/min, which is the same as L/min per square meter. Feet of water at 60 °F gives 2.309 ft per psi, or 0.433 psi per foot, the figure used for elevation in sprinkler hydraulic calculations; the conventional water column, based on 1,000 kg/m3, is listed separately. Response time index converts with the square root of the foot: 1 (ft·s)½ = 0.552 (m·s)½.

Temperature is the one quantity that does not scale: degrees Celsius and Fahrenheit carry an offset, so a reading of 100 °F is 37.8 °C while a rise of 100 °F is a rise of 55.6 K. The tool keeps the two apart as Temperature and Temperature difference, and it stops at absolute zero.

Worked example

A storage design at 0.30 gpm/ft2 is 12.2 mm/min. A K-11.2 sprinkler is 161.5 L/min/bar½ by exact conversion; the nominal SI value on the listing is K-160, and the listed value is the one to use. A design fire of 2,000 Btu/s is 2,110 kW, a target heat flux of 25 kW/m2 is about 7,925 Btu/(h·ft2), and a static pressure of 120 psi is 8.27 bar or 277 ft of water at 60 °F. A smoke exhaust rate of 10,000 cfm is 4.72 m3/s.

Assumptions and limits

The Btu and calorie are the International Table units unless a row says thermochemical. Acres and miles use the international foot, which replaced the US survey foot at the end of 2022. Pressures convert the same way whether they are gauge or absolute, so the label stays with the user. Displayed values are rounded to the chosen number of significant figures; nominal K-factors and other listed values in standards are rounded in their own way and should be taken from the listing or the standard rather than from a conversion.

When to bring in an engineer

Mixed-unit projects, such as international owners with US-listed equipment or SI drawings reviewed against NFPA standards, are where conversion slips cause real problems. DGA provides third-party review of calculations and drawings and full fire protection design in either unit system.

References

  1. A. Thompson and B.N. Taylor, Guide for the Use of the International System of Units (SI), NIST Special Publication 811, 2008 edition, National Institute of Standards and Technology: Appendix B conversion factors.
  2. National Institute of Standards and Technology, “Deprecation of the United States (U.S.) Survey Foot,” Federal Register, October 5, 2020: the international foot used for acres and miles.
  3. NFPA 13, Standard for the Installation of Sprinkler Systems, National Fire Protection Association, 2025 edition: nominal K-factors in US and SI units and the pressure of a column of water used in hydraulic calculations.

Frequently Asked Questions

How do you convert a K-factor from gpm/psi^0.5 to L/min/bar^0.5?

Multiply by 14.4163. One gallon per minute is 3.7854 L/min and one psi is 0.068948 bar, and because the pressure is under a square root the factor is 3.7854 divided by the square root of 0.068948. A K-5.6 sprinkler converts to 80.7, which is listed as the nominal K-80.

How many mm/min is 0.1 gpm/ft2?

0.1 gpm/ft2 is 4.07 mm/min, which is the same as 4.07 L/min per square meter. The factor is 40.746: one US gallon is 3.785 L and one square foot is 0.0929 square meters.

How many feet of water is one psi?

One psi is 2.31 ft of water at 60 F, or about 2.307 ft using the conventional water column at 1,000 kg/m3. Going the other way, each foot of water at 60 F is 0.433 psi, the value used for elevation changes in sprinkler hydraulic calculations.

Which Btu does the converter use?

The International Table Btu, 1,055.056 J, which is the Btu used in heat transfer and fire engineering in the US. The thermochemical Btu is about 0.07 percent smaller and rarely matters for fire protection work.

Related Tools and Services

More reference data and conversions calculators

Engineering aid only, provided as is and without warranty. Results depend on the inputs and on the simplifying assumptions of the method summarized on each tool page, and DGA has not verified them for your application. They do not replace code-required design, testing or review by the licensed engineer responsible for the project. Use of the tools is subject to the Terms of Use.

Quick inquiry

Need these results reviewed for a submittal?

Your name, a way to reach you, and where the project is. One of our licensed PEs replies within one business day. Every inquiry is confidential.

Prefer to describe it first? Open the Project Desk