Life Safety & Egress Consulting

Every building has to get people out safely. DGA Consulting evaluates occupant load, travel distance, and egress capacity per NFPA 101 and the IBC, giving architects and owners clear answers on what the code requires and practical paths to compliance.

Egress diagram: the three numbers that decide egress — occupant load, travel distance, and exit separation

What’s included

What life safety and egress consulting includes

DGA Consulting’s life safety consultants evaluate new designs, renovations, and existing buildings across New York, New Jersey, and Pennsylvania. The firm gives architects and owners clear answers on what the code requires and practical paths to compliance.

Occupant load calculations

Per use and space, per NFPA 101 and IBC.

Egress analysis

Number of exits, exit separation, travel distance, and common path evaluation.

Exit capacity calculations

Stair and door widths checked against occupant loads.

Life safety plans

Code-compliant life safety drawings for permit submissions.

Existing building evaluations

Egress assessments for renovations, change of occupancy, or due diligence.

When it applies

When life safety and egress consulting applies

When you need it

  • New construction or major renovation requiring life safety drawings for permit.
  • Change of occupancy or increased occupant load triggering egress re-evaluation.
  • Plan review comments on exits, travel distance, or occupant load.
  • Assembly, educational, or healthcare occupancies with complex egress requirements.
Illuminated emergency exit sign on a ceiling

Process

The consulting process

01

Gather

Drawings, occupancy program, and the applicable code editions for the client’s jurisdiction.

02

Calculate

Occupant loads, travel distances, and exit capacities worked through systematically.

03

Document

Life safety plans and a written analysis with code references for every conclusion.

04

Resolve

Plan review responses and AHJ coordination until approval.

FAQ

Frequently asked questions

What’s the difference between NFPA 101 and the IBC for egress?

Both address means of egress but with different structures and some different requirements. Most jurisdictions adopt one as primary with amendments, and the firm works in whichever the AHJ enforces and flags where they differ.

Can the firm evaluate an existing building?

Yes. Existing-building egress evaluations are a core service, for renovations, change of use, or pre-purchase due diligence.

What if the design cannot meet prescriptive travel distance?

Options include design modifications, additional exits, or a performance-based approach demonstrating equivalent safety. The firm advises which path fits.

Which states are you licensed in?

The firm’s engineers are licensed fire protection engineers in New York, New Jersey, and Pennsylvania.

Related services

Related services

Interior exit stairwell with handrails

Fire Code Consulting Services

Code interpretation and application across NFPA, state, and municipal frameworks.

Learn more

Fire sprinkler pipe system under inspection at a worksite

Smoke Control System Design & Testing

Smoke control design, analysis, and acceptance testing.

Learn more

Construction supervisor directing work on a modern building site

Fire Protection Engineering Design

Integrated sprinkler, alarm, and hydraulic design for new and existing buildings.

Learn more

For life safety and egress consulting, contact DGA Consulting. The firm responds within one business day.