Commissioning & integrated system testing

Modern buildings rely on multiple fire protection and life safety systems working together: sprinklers, alarms, smoke control, elevators, and access control. DGA Fire Protection Engineering provides fire protection system commissioning and integrated testing for new construction and major renovations across New York, New Jersey, Pennsylvania, Maryland, Delaware, Washington, Oregon, and Florida, verifying systems as a whole before the AHJ asks for proof. That includes witnessed acceptance testing of sprinkler, fire pump, standpipe, and fire alarm systems.

Opens the Project Desk with your sentence. Our licensed PEs review every brief and reply within one business day.

Diagram showing how a single alarm triggers elevator recall, smoke control, HVAC shutdown, door release, and occupant alert during an integrated system test

What’s Included

What commissioning and integrated system testing includes

DGA provides fire protection system commissioning and integrated testing for new construction and major renovations across New York, New Jersey, Pennsylvania, Maryland, Delaware, Washington, Oregon, and Florida. The firm’s work is led by licensed Professional Engineers, who verify that interconnected systems perform together, per NFPA 3 and NFPA 4.

Commissioning plans

Written plans defining scope, responsibilities, and acceptance criteria per NFPA 3.

Integrated testing (NFPA 4)

End-to-end testing of interconnected fire protection and life safety systems: alarm initiates, smoke control responds, elevators recall, doors release.

Test documentation

Complete records of every test, result, and deficiency resolution for the AHJ and owner. These records become the baseline for ongoing inspection, testing, and maintenance under NFPA 25 and NFPA 72.

Deficiency tracking

Systematic punch-list management through final acceptance.

Owner training support

Documentation and walkthrough materials so building staff understand the systems they are inheriting.

Witnessed acceptance tests

Sprinkler, fire pump, standpipe, and fire alarm acceptance tests observed and recorded against the design and the governing standard.

When It Applies

When commissioning and integrated system testing applies

Triggers

When you need it

  • NFPA 3 & NFPA 4 Projects: High-rise and complex projects where the adopted codes call for fire commissioning and integrated system testing.
  • Complex Facilities: Data centers, healthcare, assembly venues, and large commercial buildings with interconnected life safety systems.
  • Major Renovations: Work that adds or changes equipment tied to existing suppression, detection, or building controls.
  • Pre-Occupancy Reviews: Owners who want integration failures and sequence gaps caught before the AHJ final inspection.

What We Deliver

Commissioning & IST deliverables

  • NFPA 3 Commissioning Plans: Owner’s project requirements (OPR), basis of design (BOD) review, and inspection checkpoints.
  • NFPA 4 Integrated Test Plans: Scenario test scripts for power loss, alarm activation, and cross-system responses.
  • Sequence of Operations Verification: Functional checks of elevator recall, door release, smoke dampers, stair pressurization, and generator transfer.
  • Closeout Documentation: Test records, deficiency logs, and the integrated testing report for AHJ acceptance.

Process

The commissioning process

01

Plan

Commissioning scope, test matrix, and acceptance criteria defined up front.

02

Witness and test

Individual system tests observed, then integrated scenarios run end to end.

03

Document

Every result recorded, with deficiencies tracked to resolution.

04

Accept

Final documentation package prepared for the AHJ and owner turnover.

FAQ

Frequently asked questions

What is the difference between NFPA 3 and NFPA 4?

NFPA 3 covers commissioning of fire protection and life safety systems, which is the overall verification process. NFPA 4 covers integrated testing specifically: verifying that interconnected systems respond correctly together.

Is integrated testing required by code?

Often, yes. The International Fire Code requires integrated testing to NFPA 4 in high-rise buildings and where fire alarm is integrated with smoke control, at least every 10 years. Adopted editions and local amendments vary, so the firm confirms the requirement for each project.

Can the firm commission systems designed by someone else?

Yes. Third-party commissioning by an independent engineer is standard practice and often preferred.

Which states are you licensed in?

New York, New Jersey, Pennsylvania, Maryland, Delaware, Washington, Oregon, and Florida. Each project is sealed by a Professional Engineer licensed in the state where it is located.

Related Services

Related services

Engineers reviewing fire protection blueprints in an industrial plant

Fire alarm system design

Fire alarm and detection system design for new and existing buildings.

Learn More

Fire sprinkler pipe system under inspection at a worksite

Smoke control system design & testing

Smoke control design, analysis, and acceptance testing.

Learn More

Construction supervisor directing work on a modern building site

Standpipe system design

Standpipe system design for occupant and firefighter use.

Learn More

Quick inquiry

Ready when you are.

Your name, a way to reach you, and where the project is. A licensed PE replies within one business day. Every inquiry is confidential.

Prefer to describe it first? Open the Project Desk

FirmDGA Fire Protection Engineering
SheetFP-211
OfficesNew York · Harrisburg · Seattle
LicensedNY NJ PA MD DE WA OR FL
Rev10.2026
Sheet index