Does the Pennsylvania Fire and Panic Act Still Apply?
General guidance, not a code determination for any project. Confirm the adopted code and local amendments with the authority having jurisdiction.
Mostly no. The Pennsylvania Construction Code Act (Act 45 of 1999) repealed the Fire and Panic Act’s building classes, egress rules, plan approvals and occupancy permits, and the Uniform Construction Code (UCC) has governed new construction, alterations and changes of occupancy since 2004. What survives is a short list of sections, including fire safety rules for family child-care homes, plus the Act’s continuing role in documenting pre-2004 buildings and in waivers for buildings that were never approved.
For owners, buyers and design teams, the Act usually surfaces as an old occupancy permit from the Pennsylvania Department of Labor and Industry (L&I), or as a building that never received one. This article explains what the Act required, what replaced it and when, where the old records are kept, and what a legacy L&I permit means for a building as of November 2026.
At a Glance: The Fire and Panic Act Today
- Jurisdiction: Pennsylvania, except cities of the first class, second class and second class A (Philadelphia, Pittsburgh and Scranton), which section 15 of the Act left out.
- Local code and edition: the Fire and Panic Act (Act of April 27, 1927, P.L.465, No.299), largely repealed by Act 45 section 1102, with the sections listed in section 1101 kept; replaced by the UCC, 34 Pa. Code Chapter 403, on the 2021 International Codes (I-Codes) since January 1, 2026 (as of November 2026).
- Agency (authority having jurisdiction, AHJ): under the Act, L&I’s Bureau of Occupational and Industrial Safety approved the plans, and L&I still holds them on microfilm; today, the municipal building code official, a certified third-party agency, or L&I where a municipality opted out and for state-owned buildings.
- Filing or permit name: under the Act, an L&I plan approval and occupancy permit; today, a UCC building permit and certificate of occupancy, or a certificate of occupancy for an uncertified building under Act 45 section 902.
- Key difference from the model code: the Act sorted buildings into L&I classes (A-1 to D-H), each with set exit, alarm, extinguisher and sprinkler requirements; the UCC applies the 2021 International Building Code (IBC) and International Existing Building Code (IEBC). Proof of Fire and Panic Act compliance still supports waivers for uncertified buildings.
- Review time range (as of November 2026): no review clock exists under the Act; new work follows the UCC, under which the building code official grants or denies a commercial permit application within 30 business days (34 Pa. Code 403.43(a)) and a residential application within 15 business days (403.63(a)).
Is the Pennsylvania Fire and Panic Act Still in Force?
Only in part. Act 45 handled the 1927 law section by section: section 1102(a) repealed most of the Fire and Panic Act’s sections by number, and section 1101 listed the sections that Act 45 would not repeal or affect. The repealed sections are the ones that ran the building program, from the classes of buildings and ways of egress to plan approval and permits for use or occupancy.
The saved sections are narrower. Section 1 (the general requirement that covered buildings be constructed, equipped, operated and maintained for safety from fire and panic), section 13 (prosecutions, with a fine of up to $5,000 on conviction), section 14 (the owner’s liability for damages) and section 15 (enforcement) remain on the books. Part of section 3.6 also survives, and it still sets fire safety rules for one building type.
That building type is the family child-care home: a home, other than the child’s own, where care is provided at any one time to 4, 5 or 6 children unrelated to the operator (section 3.6(g)). Under section 3.6(f.1), last amended in 2022, the home needs a smoke alarm on each floor and in the basement, interconnected so that any alarm that activates can be heard in the indoor child-care space with all intervening doors closed, plus a portable extinguisher rated for Class B fires in the kitchen and cooking areas and exits that meet the requirements for an R-3 occupancy.
| Fire and Panic Act section | Subject | Status as of November 2026 |
|---|---|---|
| 1 | General requirement for covered buildings | In force; saved by Act 45 section 1101 |
| 2, 3, 3.1, 3.2 | Classes of buildings; special requirements; automatic fire detection for people with hearing impairments and in Class IV buildings | Repealed by Act 45 section 1102(a) |
| 4, 4.1, 4.2 | Ways of egress; fire extinguishers; legislative review of rules | Repealed by section 1102(a) |
| 5, 6, 7 | Theaters and places of public assembly; motion picture permits; projectionist licensing | Repealed by section 1102(a) |
| 8 to 12 | Approval of plans; permits for use or occupancy; discontinuance of use; failure to submit plans or to comply | Repealed by section 1102(a) |
| 3.6 | Standards for Class VI buildings | Family child-care home rules in (f)(1)(i), (f.1) and (g) in force; the rest repealed by section 1102(a) |
| 3.3, 3.5, 10.1 | Information on protection from fire; school tobacco control; clean indoor air | Left in force by Act 45, then repealed by later acts in 2016, 2019 and 2008 |
| 3.4 | Teletypewriters a municipality may install in its police headquarters | In force |
| 13, 14, 15 | Prosecutions; liability of owner; enforcement | In force; saved by section 1101 |
| 15.1 | Preemption of local rules on the subjects of sections 3.5 and 10.1 | In force; Act 128 of 2000 undid its 1999 repeal before that repeal took effect |
Status as shown in the General Assembly’s compiled text of the Fire and Panic Act and in Act 45 sections 1101 and 1102, as of November 2026.
The UCC did not take over every job the old Act did. The UCC is a construction code and Pennsylvania has no statewide fire code, so ongoing fire safety rules for occupied buildings depend on what each municipality adopts; DGA’s article on whether Pennsylvania has a statewide fire code explains how that works.
What the Fire and Panic Act Required
The Fire and Panic Act became law on April 27, 1927 (P.L.465, No.299). Its title, as amended, states the purpose: the safety of people employed, housed or assembled in certain buildings, through required construction, ways of egress, equipment and maintenance, plan examination and approval, and enforcement by L&I, with roles for the Department of Health, school boards and, in cities of the third class, fire chiefs.
The Act does not reach the largest cities. Section 15 provides that nothing in the Act affects buildings in cities of the first class, second class and second class A, the classes that cover Philadelphia, Pittsburgh and Scranton, so buildings there answered to city building codes instead.
The working rules sat in L&I’s Fire and Panic regulations, 34 Pa. Code Chapters 49 to 59, whose administrative chapter, Chapter 49, dates from May 19, 1984 in its current form. Section 49.3 required detailed plans of a covered building to be submitted to and approved by L&I’s Bureau of Occupational and Industrial Safety before the building was erected, adapted, remodeled or altered, with any required emergency lighting, fire alarm and fire extinguishing systems shown. Approval of plans and permits for use or occupancy were sections 8 and 9 of the Act, both repealed by Act 45.
L&I sorted buildings into its own classes rather than the occupancy groups used now, and each class carried its own requirements for the number of exits, travel distance, manual or automatic fire alarm, emergency lighting, fire extinguishers and automatic sprinklers. L&I still publishes a one-page summary of those classes and requirements. The right-hand column of the table is DGA’s approximate match to the 2021 IBC, because the two systems do not map one to one.
| Fire and Panic class | Buildings it covered | Nearest 2021 IBC group (approximate) |
|---|---|---|
| A-1, A-2, A-3 | Assembly for amusement, worship, transportation, recreation, dining and similar uses, split into three classes by occupant load | Group A |
| B | Education, instruction and day care | Group E; some day care falls in Group I-4 |
| C-1 | Health care with sleeping rooms for people mostly incapable of self-preservation, such as hospitals and nursing homes | Group I-2 |
| C-2 | Group habitation: hotels, apartments, dormitories and large personal care homes | Groups R-1 and R-2; large personal care homes Group R-4 or I-1, by number of residents |
| C-3 | One living unit housing 4 to 8 residents, such as small personal care homes and group homes | Group R-3 or R-4, by number of residents |
| C-4 | Apartment units with a single means of egress | Group R-2 |
| D-O | Manufacturing, assembly, warehousing, sale or storage of combustible but not highly flammable materials, and offices | Groups B, F-1, M and S-1 |
| D-H | Highly combustible, explosive or unstable materials | Group H |
Classes from L&I’s one-page summary of the Fire and Panic Act classifications and the major safety requirements for each. The IBC column is DGA’s reading, not an official conversion.
What Replaced the Fire and Panic Act, and When
The replacement is the Pennsylvania Construction Code Act, enacted November 10, 1999 (P.L.491, No.45), and the UCC regulations L&I adopted under it. Act 45 did not end the Fire and Panic Act on enactment: the repeal in section 1102 waited until the UCC regulations were in place.
The UCC regulations use April 9, 2004 as the dividing date. Under 34 Pa. Code 403.101(c), the Fire and Panic Act, the Universal Accessibility Act and local building codes still govern new buildings and renovations whose permit application was made, or whose design or construction contract was signed, before that date. Section 403.1(d)(1) kept a permit issued under the earlier regulations valid if construction started within 2 years of issuance, or a shorter period set by municipal ordinance.
Municipalities also had an election window. Section 403.101(a) kept the old law in effect in each municipality until it adopted a UCC ordinance and notified L&I, opted out of local enforcement, or let the initial election period close on August 7, 2004. After that date the old law governed only work grandfathered under Section 403.101(c).
Figure 1: From the Fire and Panic Act to the UCC
As of November 2026, the UCC is based on the 2021 I-Codes, adopted through Regulation #12-125 and effective January 1, 2026. The comparison below shows how the two regimes answer the same questions.
Figure 2: Fire and Panic Act vs the UCC
| Topic | Fire and Panic Act (1927) and L&I regulations | UCC (Act 45 of 1999), 2021 I-Codes since January 1, 2026 |
|---|---|---|
| Where it applies | Covered buildings outside cities of the first class, second class and second class A (section 15) | Statewide, including Philadelphia and Pittsburgh; enforced by the municipality, a certified third-party agency or L&I (34 Pa. Code 403.102, 403.141) |
| Building categories | L&I classes A-1 to A-3, B, C-1 to C-4, D-O and D-H | 2021 IBC occupancy groups |
| Plan review | L&I Bureau of Occupational and Industrial Safety, before a covered building was erected, adapted, remodeled or altered (34 Pa. Code 49.3) | The building code official with jurisdiction, who grants or denies a commercial application within 30 business days (403.43(a)) |
| Fire protection rules | Exits, travel distance, fire alarm, emergency lighting, extinguishers and sprinklers set class by class | 2021 IBC Chapters 9 and 10; fire protection shop drawings approved before installation (403.42a(f)(3)) |
| Approval for use | L&I occupancy permit (Act sections 8 and 9, now repealed) | Certificate of occupancy; a legal occupancy existing on April 9, 2004 may continue (403.1(d)(3)) |
| Existing buildings | L&I plan approval before a covered building was adapted, remodeled or altered | Alterations, additions and changes of occupancy under the UCC, including the 2021 IEBC; uncertified buildings under Act 45 section 902 |
The largest practical change is who reviews the plans. Under the Fire and Panic Act, L&I reviewed covered buildings across the state outside the excluded cities; under the UCC, L&I says more than 90 percent of municipalities enforce the code locally, and L&I enforces it for most nonresidential buildings where a municipality opted out and for state-owned buildings everywhere (Section 403.141). DGA’s guides to who reviews fire protection plans in Pennsylvania and how fire protection plan review works under the UCC cover the current path.
DGA reviews legacy approvals and prepares code analyses for existing buildings across New York, New Jersey, Pennsylvania, Maryland and Delaware. Project briefs get confirmation and preliminary code feedback within one business day. See where DGA works →
Who Holds the Old Fire and Panic Act Records
L&I holds the approved plans. According to L&I’s Right-to-Know Law page, the department keeps copies of all construction plans submitted and approved as part of a Fire and Panic or UCC permit application, preserved on 35 mm microfilm, and reproduced copies come out at a much smaller scale than the original sheets.
Those plans are not public records. L&I treats building plans as a security matter and releases them only to the building owner, the design professional of record who designed and sealed the original approved plans, or a third party the owner designates. A buyer, tenant or lender therefore needs the owner’s designation before L&I will release a set.
L&I does not keep the occupancy permits. The department states that it does not retain copies of occupancy permits once they are issued, but it will generate a duplicate permit at the building owner’s request.
Two kinds of records sit elsewhere. Buildings in Philadelphia, Pittsburgh and Scranton fall outside the Act under section 15, so a Fire and Panic Act search at the state is unlikely to find their earlier approvals, and Philadelphia’s Department of Licenses and Inspections, also called L&I, is a city agency separate from the state department. Permits and certificates of occupancy issued since 2004 in a municipality that enforces the UCC usually came from its building code official or third-party agency, so the municipality is the first place to ask.
A records request belongs early in due diligence. The approved plans show the exits and the alarm, emergency lighting and extinguishing systems L&I accepted, and together with the occupancy permit they document the baseline that any later alteration or change of use starts from.
What a Legacy Labor and Industry Permit Means Today
An L&I occupancy permit issued under the Fire and Panic Act still matters because the UCC protects existing legal occupancies. Under 34 Pa. Code 403.1(d)(3), the legal occupancy of a structure that existed on April 9, 2004 may continue without change, except where the UCC provides otherwise, and the old permit is the usual evidence of what that occupancy was.
That protection ends where new work begins. Section 403.42(a) requires a permit before a commercial building is constructed, enlarged, altered, repaired or changes occupancy, and the work is reviewed under the UCC, including the 2021 IEBC, not under the Fire and Panic Act.
A building that never received an approval follows a separate path. Act 45 section 103 defines an uncertified building as an existing building, other than a residential building, that was not approved for use and occupancy before April 9, 2004 by L&I or by a municipality that was enforcing a building code. Section 902 lets such a building obtain a certificate of occupancy: L&I issues it against a defined list of IBC requirements where L&I has jurisdiction, and the municipal code official issues it under section 902(c) elsewhere.
The Fire and Panic Act enters that list as a waiver ground. L&I may waive an item on the building and egress list or the fire safety list where the owner demonstrates that the building met the corresponding egress or fire safety requirements that existed under the Fire and Panic Act, or where the requirement is technically infeasible, and each waiver must be documented on the certificate of occupancy (section 902(b)(2)).
| Act 45 section 902 provision | What it requires or allows |
|---|---|
| Building and egress, 902(b)(2)(i) | Under the IBC: maximum story height, minimum construction type for the floor area, vertical opening and shaft protection, minimum number of exits, maximum travel distance to exits, means of egress illumination, and minimum widths and heights of exit doors, stairs, ramps and corridors; width and height may be waived where nonconforming openings still let occupants pass through |
| Fire safety, 902(b)(2)(ii) | IBC requirements for fire alarms, fire extinguishers, heat and smoke detectors, automatic sprinkler systems, and occupancy and incidental use separations |
| Sprinkler limits, 902(b)(2)(ii) | Where the IBC calls for sprinklers, only Groups E, H, I, R-1 and R-2 and buildings with occupied floors more than 75 ft above the lowest level of fire department access must install them; none are required under this section where construction began before May 19, 1984 |
| Detector alternative, 902(b)(2)(ii) | Groups R-1 and R-2 with no occupied floor more than 75 ft above that level may install hard-wired, interconnected heat and smoke detectors in lobbies, corridors, equipment rooms, storage rooms and other spaces not normally occupied instead of sprinklers |
| Fire and Panic Act waiver, 902(b)(2) | Egress and fire safety items may be waived where the owner shows the building met the Fire and Panic Act requirements, or where a requirement is technically infeasible; each waiver is documented on the certificate of occupancy |
| Current occupancy, 902(b)(5) | The building may keep its current occupancy as long as the owner demonstrates reasonable efforts to comply |
| Pre-1927 buildings, 902(b)(6) | An uncertified building built before April 27, 1927 is deemed a certified building |
| Municipal path, 902(c) | Outside L&I’s jurisdiction, the construction code official issues the certificate of occupancy, applying the latest IEBC or another standard that section 902(c) allows, whichever the official judges applies best |
Section 902(d) adds that this path does not displace the UCC when an uncertified building is renovated, added to, altered or changes use or occupancy. Variances from the section 902(b) list, other than accessibility, go to the Industrial Board where L&I has jurisdiction or the building is state-owned (section 902(b)(4)); DGA’s guide to appeals and variances under the Pennsylvania UCC covers the boards and their hearing timelines.
Figure 3: Does the Fire and Panic Act Still Matter for This Building?
In practice, the documents decide the path. A building with an L&I occupancy permit and approved plans on microfilm starts from a documented baseline. A nonresidential building with no record of approval from L&I or an enforcing municipality before April 9, 2004 is likely an uncertified building, and section 902 sets what it must show to obtain a certificate of occupancy.
Key Takeaway: The Fire and Panic Act no longer governs design or permits in Pennsylvania: Act 45 of 1999 repealed its building sections, and the UCC has controlled new work since 2004, on the 2021 I-Codes since January 1, 2026. The Act still matters as evidence and as a waiver ground, because an L&I occupancy permit documents a legal occupancy that may continue under 34 Pa. Code 403.1(d)(3), Fire and Panic Act compliance supports waivers for uncertified buildings under Act 45 section 902, L&I keeps the approved plans on microfilm for the owner, and family child-care homes still follow section 3.6(f.1).
Frequently Asked Questions
Is a Fire and Panic Act occupancy permit still valid?
Yes, for the use it approved. Under 34 Pa. Code 403.1(d)(3), the legal occupancy of a structure that existed on April 9, 2004 may continue without change except where the Uniform Construction Code provides otherwise, and the old permit is the usual evidence of that occupancy. An alteration, addition or change of occupancy needs a permit under the Uniform Construction Code and is reviewed under it, not under the Fire and Panic Act.
Does the Fire and Panic Act apply to buildings built before the UCC?
No, not to new work on them. Act 45 section 1102(a) repealed the Act’s building sections, so alterations, additions and changes of occupancy in a pre-2004 building follow the Uniform Construction Code. The Act still counts in another way: the owner of an uncertified building can show that the building met the Fire and Panic Act’s egress or fire safety requirements to support waivers under Act 45 section 902(b).
Where are old Labor and Industry approvals kept?
The Department of Labor and Industry keeps the approved plans but not the occupancy permits. It holds plans approved under the Fire and Panic Act or the Uniform Construction Code on 35 mm microfilm and releases them only to the building owner, the design professional of record or a third party the owner designates. It does not retain copies of occupancy permits once issued, but it will generate a duplicate permit at the building owner’s request.
Does the Fire and Panic Act apply in Philadelphia or Pittsburgh?
No. Section 15 of the Act states that nothing in it affects buildings in cities of the first class, second class and second class A, the classes that cover Philadelphia, Pittsburgh and Scranton. Buildings in those cities answered to city building codes before the Uniform Construction Code, which applies there today.
What is an uncertified building in Pennsylvania?
An existing building, other than a residential building, that was not approved for use and occupancy before April 9, 2004 by the Department of Labor and Industry or by a municipality that was enforcing a building code (Act 45 section 103). Section 902 gives such a building a path to a certificate of occupancy against a defined list of building code egress and fire safety items, allows waivers where the building met the Fire and Panic Act’s requirements, and treats a building built before April 27, 1927 as certified.
More in Approvals by Jurisdiction
- How Does AHJ Review Work in NYC, NJ and Philadelphia?
- How Do Pittsburgh Fire Protection Approvals Work?
- How Do Federal Agencies Review Leased-Space Fire Protection?
- What Is Maryland’s Sprinkler Law for New Homes?
- What Does NYC Require for Construction Site Fire Safety?
- Does NYC Local Law 97 Affect Fire Protection Systems?
This article is general information, not a code determination or legal advice for any building. Statutes, regulations and agency practice change; confirm the status of a building’s approvals and the code that applies with L&I or the municipal building code official.
Working With a Pre-2004 Pennsylvania Building?
Send the address, the current use and any L&I occupancy permit or plan approval on file. DGA reads the legacy approval against the UCC, identifies what an alteration or change of occupancy will trigger, and sets out the section 902 path for a building that was never certified. Project briefs get confirmation and preliminary code feedback within one business day.