Free Engineering Tool · NUREG-1805

Pool Fire Radiation Calculator

Enter the fire size, the pool diameter and where the target is. The calculator estimates the radiant heat flux by the point source and solid flame models, finds the distance at which the flux drops to a chosen level, and shows how quickly exposed skin would feel pain or burn, following NUREG-1805 Fire Dynamics Tools.

  • Based on NUREG-1805
  • Free, runs in your browser; your inputs stay on your device
  • Screening tool, not reviewed or sealed by a licensed engineer
  • Last updated October 2026

Screening tool, not engineering advice. This calculator estimates results with simplified published methods. It has not been reviewed or sealed by a licensed engineer for your project, and DGA does not warrant that its results are accurate, complete or suitable for any use. Check every result independently and have the licensed professional responsible for your project review it before you rely on it. Use is subject to the Terms of Use.

Advanced method. The correlations behind this tool come from research and test data with narrow ranges of validity. Outside those ranges results can be wrong by a wide margin, and they are no substitute for a fire model or an analysis by a qualified fire protection engineer.

Fire

Use the pool fire heat release rate calculator to get the heat release rate from the fuel and pool size. For a non-circular pool, enter the diameter of a circle of the same area.

Target

Result

Incident heat flux
0
Point source model
0
Solid flame model
0
Separation distance
0

Heat Flux and Distance

Keep these results

About This Tool

Most of the danger from an open pool fire beyond the flames is thermal radiation. Two screening models are in common use. The point source model treats the fire as a single point on the pool axis at half the flame height that radiates a fraction χr of the heat release rate equally in all directions: q″ = χr Q cosθ / (4πR2), where R is the distance from that point to the target and θ is the angle between the target’s normal and the line of sight. A radiative fraction of 0.30 is the screening value used in NUREG-1805; large smoky pools radiate less, and a fit to large-pool tests gives about 0.21 − 0.0034 D.

The solid flame model of Shokri and Beyler treats the flame as a vertical cylinder the diameter of the pool and the height given by the Heskestad correlation, H = 0.235 Q2/5 − 1.02 D. The flux is q″ = E F, where the average emissive power E = 58 × 10−0.00823D kW/m² falls as larger pools produce more black smoke, and F is the configuration factor from the target to the cylinder. A target above the base of the fire is handled by splitting the flame into two cylinders at the target’s height. Validation against large pool tests found the point source model works best below about 5 kW/m² and the solid flame model at and above 5 kW/m², so the headline result uses the model suited to the flux level. Both models overpredicted most of the test data once a factor of 2 was applied, which is why a design safety factor is offered.

The separation distance is found by stepping out from the pool until the flux falls to the value entered, using the model suited to that level. People feel pain when skin temperature at the pain receptors reaches about 45 °C. Simplified correlations with safety factors give the time to pain as 125 q″−1.9 seconds and the time to a superficial second-degree burn as 260 q″−1.56 seconds (q″ in kW/m²); below 1.7 kW/m² no pain is reported however long the exposure.

Worked example

A 6 ft (1.83 m) gasoline pool releases about 6,180 kW. Its flame is 5.85 m (19.2 ft) tall. For a wall 20 ft (6.10 m) from the pool edge, the point source sits 2.93 m above the pool center and 7.60 m from the base of the wall, so cosθ = 7.01 / 7.60 = 0.923 and q″ = 0.30 × 6,180 × 0.923 / (4π × 7.602) = 2.4 kW/m². The solid flame model gives E = 56.0 kW/m² and a vertical configuration factor of 0.052, or 2.9 kW/m². Since both are below 5 kW/m², the point source value of 2.4 kW/m² is the headline result. The flux reaches 5 kW/m² about 12 ft (3.8 m) from the edge, and at 2.4 kW/m² a person would feel pain in about 24 seconds.

Assumptions and limits

The fire is a steady, upright pool fire in still air. Wind tilts the flame toward downwind targets and can raise the flux there several times; the hot plume, smoke layers and convective heating are not included. Absorption by the air between the flame and the target is ignored, which is conservative. The models were fitted to hydrocarbon pools from about 1 to 50 m in diameter. Clothing, shielding and escape behavior change real exposure times considerably.

When to bring in an engineer

Radiation from pool fires sets spacing for tanks, loading racks, transformer yards and exterior egress paths, and decides whether neighboring structures or equipment need protection. DGA runs these analyses as part of fire modeling and equivalency reports where a performance-based separation is proposed.

References

  1. Iqbal, N., and Salley, M.H., Fire Dynamics Tools (FDTs): Quantitative Fire Hazard Analysis Methods for the U.S. Nuclear Regulatory Commission Fire Protection Inspection Program, NUREG-1805, U.S. Nuclear Regulatory Commission, 2004, Chapter 5.
  2. Shokri, M., and Beyler, C.L., “Radiation from Large Pool Fires,” Journal of Fire Protection Engineering, 1 (4), 1989, pp. 141 to 150.
  3. Heskestad, G., “Luminous Heights of Turbulent Diffusion Flames,” Fire Safety Journal, 5 (2), 1983, pp. 103 to 108.
  4. Drysdale, D., An Introduction to Fire Dynamics, 3rd ed., Wiley, 2011: the point source radiation model.
  5. Wieczorek, C.J., and Dembsey, N.A., “Human Variability Correction Factors for Use with Simplified Engineering Tools for Predicting Pain and Second Degree Skin Burns,” Journal of Fire Protection Engineering, 11 (2), 2001, pp. 88 to 111.
  6. NFPA 921, Guide for Fire and Explosion Investigations, National Fire Protection Association, 2024 edition: radiant heat transfer from fires.
  7. NFPA 59A, Standard for the Production, Storage, and Handling of Liquefied Natural Gas (LNG), National Fire Protection Association, current edition: radiant heat flux exposure limits.

Frequently Asked Questions

What is the difference between the point source and solid flame models?

The point source model lumps the fire’s radiation into one point at half the flame height and falls off with the square of distance. The solid flame model treats the flame as a cylinder with a measured average emissive power and uses the geometric view of that cylinder from the target. The solid flame model is the better estimate at 5 kW/m2 and above; the point source model is simpler and works well farther away, below 5 kW/m2.

How much radiant heat flux can a person tolerate?

Below about 1.7 kW/m2 people do not report pain however long the exposure. At 5 kW/m2 the simplified correlations predict pain in about 6 seconds and a superficial second-degree burn in about 21 seconds, so 5 kW/m2 is often used as a limit for places where people may be exposed briefly, such as escape routes.

How far from a pool fire is safe?

It depends on the fire size, the flux limit for the target and how long it is exposed. Enter the heat release rate, pool diameter and limit in the calculator; it reports the distance from the pool edge at which the predicted flux falls to that limit. Apply a safety factor for design, and consider wind tilting the flame toward the target.

What radiative fraction should I use?

A value of 0.30 is a common screening value. Large, smoky hydrocarbon pools radiate a smaller fraction because smoke hides the luminous flame; tests suggest about 0.21 minus 0.0034 times the diameter in meters, roughly 0.20 for small pools and 0.13 at 25 m. Clean-burning fuels such as alcohols also radiate less.

Related Tools and Services

More flammable liquids, gases and radiation calculators

Engineering aid only, provided as is and without warranty. Results depend on the inputs and on the simplifying assumptions of the method summarized on each tool page, and DGA has not verified them for your application. They do not replace code-required design, testing or review by the licensed engineer responsible for the project. Use of the tools is subject to the Terms of Use.

Related Reading

Articles from DGA Insights on the code and the method behind this calculator.

Quick inquiry

Need these results reviewed for a submittal?

Your name, a way to reach you, and where the project is. One of our licensed PEs replies within one business day. Every inquiry is confidential.

Prefer to describe it first? Open the Project Desk