Approvals by Jurisdiction · Definition
What Is an AHJ and How Do You Find Yours?
General guidance, not a code determination for any project. Confirm the adopted code and local amendments with the authority having jurisdiction.
An authority having jurisdiction (AHJ) is the office or official with the power to enforce a code on a project and to accept or reject the work done under it. Many fire protection projects have more than one: a building official who issues the permit, and a fire official, fire marshal or state reviewer who approves the fire protection systems or enforces the fire code.
The code book does not say who the AHJ is for a given address. State and local law does, and the answer changes with the state, the municipality and who owns the building. This article explains what the term means, where the codes define it, how it differs from the titles it is confused with, and how to identify the AHJ for a project in New York, New Jersey, Pennsylvania, Maryland and Delaware.
At a Glance: Authority Having Jurisdiction (AHJ)
- Definition: whichever office or official holds the power to enforce a code on a project and to accept or reject the work done under it.
- Governing code and section: the National Fire Protection Association (NFPA) official definitions in Chapter 3 (the AHJ at Section 3.2.2) of NFPA documents such as NFPA 1, NFPA 13 and NFPA 101; the International Building Code (IBC) and International Fire Code (IFC) assign the same role to the building official and the fire code official in Section 104. State law names the actual office.
- Who it applies to: every permitted project; owners, design professionals and contractors submit to it, and its approval is what lets work start, close in and be occupied.
- When it’s required: whenever a code calls for a permit, plan review, inspection or test, or uses the word “approved”.
- Typical output: a permit or plan approval, an inspection sign-off, a certificate of occupancy, an operating permit, or a written acceptance of an alternative method.
- Often confused with: “the fire marshal” or “the building department” alone. The AHJ is whichever office holds authority over the specific item, and one building usually has several.
What Is an Authority Having Jurisdiction?
An authority having jurisdiction is defined by its function, not its title. NFPA’s definition, in Section 3.2 of documents such as NFPA 1, NFPA 13 and NFPA 101, describes the AHJ by two powers, enforcement and approval, and names no title or agency. Any office that holds that power over a project is an AHJ for that project, whether it is called a building department, a fire marshal’s office, a construction office or a state bureau.
The AHJ matters because NFPA standards leave many decisions to it. In NFPA documents, the word “approved” is defined by reference to the AHJ, so every approved device, arrangement or test result depends on its sign-off. NFPA 13 (2022), for example, requires the water supply flow test used for sprinkler design to be no more than 12 months old at working plan submittal unless the AHJ approves otherwise (Section 4.5.1.1).
Who Can Be an AHJ: the Offices That Hold the Role
NFPA’s annex note to the definition makes clear that the role is not limited to government. Besides public fire, building and electrical officials at any level of government, it recognizes insurers for insurance purposes, owners acting through their own representatives, and military or agency officials on government property. The table sorts those roles by what each one approves in the five states DGA works in.
| Type of AHJ | What it approves | Example |
|---|---|---|
| Building official | Construction documents, the building permit, construction inspections and the certificate of occupancy | A New Jersey municipal construction official; a Pennsylvania municipal building code official; the New York City Department of Buildings (DOB) |
| Fire protection subcode official | Plan review and inspection of sprinklers, standpipes, fire alarm, fire pumps and related systems within the building permit | The New Jersey fire protection subcode official under the New Jersey Administrative Code (N.J.A.C.) 5:23-3.17, with scope set by the tables in 5:23-3.4 |
| Fire code official, fire marshal or fire official | Fire code compliance in new and existing buildings, operating permits, periodic inspections and, in some states, fire protection plan review | The Maryland and Delaware Offices of the State Fire Marshal; a New Jersey local fire official; the Fire Department of the City of New York (FDNY) |
| State reviewing agency | Plans for buildings a local office cannot or does not review, and state-owned buildings | New Jersey’s Bureau of Construction Project Review; Pennsylvania’s Department of Labor and Industry (L&I); New York State agencies under Title 19 of the New York Codes, Rules and Regulations (19 NYCRR), Part 1204 |
| Third-party agency acting for the AHJ | Plan review or inspection on behalf of the enforcing office, which keeps the authority | Pennsylvania certified third-party agencies (34 Pa. Code 403.102(g)); Prince George’s County, Maryland, Third-Party Review Program for sprinkler and alarm shop drawings |
| Federal owner | Fire protection design and acceptance on federally owned property | The U.S. General Services Administration (GSA) Regional Fire Protection Engineer in responsible charge, who functions as building official, fire code official and AHJ under GSA order PBS 5921.1 |
| Insurer | Property protection requirements under the insurance policy | An insurer’s loss prevention engineers, who review protection as a condition of coverage |
The insurer and the owner differ from the others in one way: they have no permit power. Their requirements bind through a contract or a policy, so they add to the public approvals and never replace them.
Where the Codes Define the AHJ
NFPA defines the term in Chapter 3 of each code and standard, in Section 3.2, NFPA Official Definitions, at 3.2.2 with an annex note at A.3.2.2, which carries the same definition across documents such as NFPA 1, NFPA 13 and NFPA 101. The annex note to the definition explains who can fill the role; annex material is explanatory and not part of the enforceable text.
The International Code Council (ICC) codes rarely use the phrase. The IBC gives the role to the building official and the IFC to the fire code official, and Section 202 of each code defines the title by that role. Section 104 of each code sets the official’s duties and powers, including the authority to interpret the code and to approve alternative materials, designs and methods.
Neither family of codes names the office for a particular town. That comes from state law, such as N.J.A.C. 5:23-3.17 for the New Jersey fire protection subcode, the Code of Maryland Regulations (COMAR) 29.06.01.04A for the Maryland State Fire Prevention Code, 16 Del.C. 6612 for Delaware’s fire marshals, 19 NYCRR Part 1203 for New York’s local code programs, and 34 Pa. Code 403.102 for Pennsylvania municipalities.
AHJ vs Code Official vs Fire Marshal vs Fire Official vs Insurer
These titles overlap, and each one is an AHJ only for the items its law covers. A building official or code official enforces the building code through the permit. A fire marshal is an office created by state or local law, often with fire code enforcement, plan review or fire investigation duties. A fire official is the officer who enforces a fire code locally: New Jersey uses the title under the Uniform Fire Code, and Maryland’s fire prevention code lets a legally designated county or municipal fire official enforce it.
Figure 1: Building Official vs Fire Official
- Enforces the building code, an IBC base in all five states
- Reviews construction documents and issues the permit
- Inspects the work and issues the certificate of occupancy
- Powers in IBC Section 104 and the state administrative rules
- Examples: NJ construction official, PA building code official, NYC DOB
- Enforces the fire code, IFC or NFPA 1 based, in new and existing buildings
- Issues operating permits and runs periodic inspections
- Reviews fire protection plans in Maryland, Delaware and for FDNY filings in NYC
- Powers in IFC Section 104 or the state fire prevention rules
- Examples: NJ fire official, MD and DE State Fire Marshal, FDNY
An insurer is a separate track. NFPA recognizes an insurer as an AHJ for insurance purposes, but an insurer cannot issue a permit or a certificate of occupancy, and a public AHJ is not bound by the insurer’s standard. A design that satisfies the building and fire officials can still fall short of the insurer’s requirements, and the reverse is also true.
When a Project Needs the AHJ’s Approval
A project needs the AHJ whenever the code calls for a permit, plan review, inspection or acceptance test. New fire protection systems, changes to existing systems, changes of occupancy and most tenant fit-outs that touch sprinklers or alarms all require a filing. The AHJ is also the office that accepts an alternative to a prescriptive requirement, such as an equivalency under Section 104 of the IBC or IFC, the State Fire Marshal’s alternatives under Delaware Regulation 701 Section 1.7, or alternative methods approved under COMAR 29.06.01.04B in Maryland.
DGA identifies the reviewing authorities for a project and prepares the fire protection submissions they expect across New York, New Jersey, Pennsylvania, Maryland and Delaware. Project briefs get confirmation and preliminary code feedback within one business day. See where DGA works →
How to Find the AHJ for a Project in NY, NJ, PA, MD and DE
Finding the AHJ takes three questions, asked in order: who owns the building, which municipality it sits in and whether that municipality enforces the code, and which office the state assigns to the fire code. The decision tree shows the first cut, and the table gives the titles and lookup source for each state as of November 2026.
Figure 2: Finding the AHJ for a Fire Protection Project
| Jurisdiction | Codes (as of November 2026) | Building AHJ | Fire AHJ | How to look it up |
|---|---|---|---|---|
| New York State (outside NYC) | 2025 Uniform Code (2024 I-Codes), in effect since December 31, 2025 | City, town or village code enforcement official; the county, or the Department of State (DOS), where a locality opted out under Executive Law 381(2); state agencies for state buildings (19 NYCRR Part 1204) | The same local code program, which issues operating permits and runs fire safety inspections (19 NYCRR 1203.3(g) and (h)); in Nassau County the County Fire Marshal’s Office also reviews fire and life safety system plans | The city, town or village building department |
| New York City | 2022 NYC Construction Codes and 2022 NYC Fire Code | DOB: construction documents, permits and sign-offs, including sprinkler (SP) and standpipe (SD) work in DOB NOW: Build | FDNY: fire alarm, emergency alarm, fire protection plans and non-water suppression since Local Law 195 of 2018, plus Fire Code operation and maintenance | Sort the scope by system: DOB NOW: Build for DOB work, FDNY Business for FDNY filings |
| New Jersey | Uniform Construction Code (UCC) on the 2024 I-Codes since August 17, 2026; Uniform Fire Code on the 2018 IFC | Municipal construction official, with the fire protection subcode official for sprinklers, standpipes, alarms and fire pumps; the Department of Community Affairs (DCA) Bureau of Construction Project Review for Class 1 and 2 structures the local office is not classified to review (N.J.A.C. 5:23-4.24) | Local enforcing agency fire official under the Uniform Fire Code (N.J.A.C. 5:70) for existing buildings, Life Hazard Use registration and fire code permits | The municipal construction office; DCA’s Bureau of Construction Project Review page lists project types that always go to the state |
| Pennsylvania | UCC on the 2021 I-Codes since January 1, 2026; no statewide fire code | Municipal building code official or its certified third-party agency (34 Pa. Code 403.102(g)); L&I for commercial work in opt-out municipalities and for state-owned buildings (403.103, 403.141); Philadelphia’s Department of Licenses and Inspections in the city | Only where a municipality adopted a fire code by ordinance; otherwise fire protection plans are reviewed with the building permit | L&I’s Municipal Elections and Contact List, a county-by-county table of all 2,562 municipalities |
| Maryland | Maryland Building Performance Standards on the 2021 IBC; State Fire Prevention Code, NFPA 1 and NFPA 101 (2024) | County or municipal building official issuing the permit (COMAR 09.12.51) | State Fire Marshal or a legally designated county or municipal fire official (COMAR 29.06.01.04A); the Office of the State Fire Marshal (OSFM) for state-owned property | The county permitting office, which supplies the Fire Marshal Plan Review form where OSFM reviews; OSFM’s inspections page lists local fire contacts |
| Delaware | State Fire Prevention Regulations, Regulation 701 (2026), with NFPA 1 and NFPA 101 (2024); IBC by county (New Castle and Sussex 2021, Kent and Wilmington 2018) | County building official in New Castle, Kent or Sussex; the City of Wilmington Department of Licenses and Inspections inside the city | Office of the State Fire Marshal, which reviews all plans before construction (Regulation 701, Section 1.5.1.2) except where a city fire marshal holds exclusive jurisdiction under 16 Del.C. 6612(c) | The State Fire Marshal division for the county, or the city fire marshal; the State Fire Marshal’s page lists city fire marshals in Dover, Newark, the City of New Castle and Wilmington |
Statewide adoptions only. Local amendments and county fire codes are not shown.
Maryland adds two local details. The fire reviewer can sit inside the permitting department: Montgomery County’s Department of Permitting Services issues its own Fire Protection System and Fire Alarm System permits, and Prince George’s County routes fire reviews through the Fire and Life Safety Section of its building plan review division. Baltimore City is outside the State Fire Prevention Code except for buildings covered by Public Safety Article Title 6, Subtitle 4 (COMAR 29.06.01.03C), and the Baltimore City Fire Department’s Office of the Fire Marshal reviews fire protection work there.
The filing steps behind each AHJ are covered elsewhere. DGA’s guide to AHJ review in NYC, New Jersey and Philadelphia walks through what reviewers expect in a submittal, and the article on who reviews fire protection plans in Pennsylvania explains the municipal, third-party and L&I paths. Published review clocks for each state are compared in how long fire protection plan review takes by state.
When a Project Has More Than One AHJ
Many commercial projects answer to two or more AHJs, and each one reviews only its own scope. In New York City, a building with sprinklers, a standpipe and a fire alarm needs SP and SD permits at DOB and a separate fire alarm filing at FDNY, and neither agency closes the job for the other; the split is set out in DOB or FDNY: who approves what in New York City.
New Jersey divides authority by building stage. The construction official and subcode officials govern construction under the UCC, and N.J.A.C. 5:23-3.4(b) has the construction official settle conflicts between subcode officials who share a responsibility. Once the building is occupied, the local fire official enforces the Uniform Fire Code. Its fire prevention code subchapter cannot be the basis for a retrofit, which, with limited exceptions, comes from the Fire Safety Code (N.J.A.C. 5:70-4) or the UCC in force at construction, and suspected UCC violations go back to the construction official (N.J.A.C. 5:70-3.1(d)).
Maryland and Delaware run two code tracks on one building. The county or city building official applies the IBC, while the fire marshal applies NFPA 1 and NFPA 101, so each item has to satisfy both reviewers. In Wilmington, the city’s building code amendments require Fire Marshal’s Office approvals before the Department of Licenses and Inspections issues the final permit on projects with fire protection systems.
Federal and leased space adds another layer. GSA order PBS 5921.1 says leased space must meet state and local codes plus the lease requirements, so a GSA lease puts the regional fire protection engineer on top of the local AHJs, not in place of them. An insurer’s requirements, where they apply, sit on top of all of these.
Key Takeaway: An AHJ is whichever office holds the legal power to enforce a code on a project and accept or reject the work, not a single title. NFPA defines the role in Section 3.2 of its codes, the IBC and IFC give it to the building official and fire code official, and state law decides which office holds it for a given building. In New York City, New Jersey, Maryland and Delaware, expect at least two: one for the building permit and one for the fire code.
Frequently Asked Questions
Is an insurance company an AHJ?
Conditional: for insurance purposes, yes. NFPA’s annex note to the definition recognizes that an insurer can act as an AHJ where insurance coverage is the question. An insurer cannot issue a permit or a certificate of occupancy, so its requirements bind the owner through the policy, in addition to the building and fire officials’ approvals.
Can a building have two AHJs?
Yes. Many commercial projects have at least two: a building official who permits the construction and a fire official or fire marshal who enforces the fire code. New York City splits fire protection between DOB and FDNY, and Maryland and Delaware projects answer to a county or city building official and a fire marshal applying NFPA 1 and NFPA 101.
Who is the AHJ in New York City?
The Department of Buildings and the Fire Department, split by system. DOB permits sprinkler and standpipe work in DOB NOW: Build, while FDNY has reviewed fire alarm, emergency alarm, fire protection plan and non-water suppression filings since Local Law 195 of 2018. FDNY also enforces the 2022 NYC Fire Code for every installed system.
What is the difference between a fire marshal and a fire official?
A fire marshal is an office created by state or local law, often with fire code enforcement, plan review or fire investigation duties; a fire official is the officer who enforces a fire code locally. New Jersey uses “fire official” under its Uniform Fire Code, and Maryland lets the State Fire Marshal or a legally designated county or municipal fire official enforce the State Fire Prevention Code (COMAR 29.06.01.04A). Which one is the AHJ depends on the law that created the office, not the title.
More in Approvals by Jurisdiction
- How Does AHJ Review Work in NYC, NJ and Philadelphia?
- How Do Pittsburgh Fire Protection Approvals Work?
- How Do Federal Agencies Review Leased-Space Fire Protection?
- What Is Maryland’s Sprinkler Law for New Homes?
- Does the Pennsylvania Fire and Panic Act Still Apply?
- What Does NYC Require for Construction Site Fire Safety?
This article is general information, not a code determination for any project. The office that reviews a project depends on its address, ownership and scope; confirm it with the local permit office before filing.
Not Sure Who Reviews the Project?
Send the address, the owner type and the scope. DGA identifies the building and fire authorities, sets out which filing goes to which office and prepares the fire protection submissions. Project briefs get confirmation and preliminary code feedback within one business day.