Standpipes give firefighters, and in some buildings occupants, water access throughout a structure, with system class, pipe sizing, and pressure requirements governed by NFPA 14. DGA Fire Protection Engineering designs standpipe systems for commercial, residential, and mixed-use buildings across New York, New Jersey, Pennsylvania, Maryland, Delaware, Washington, Oregon, and Florida, handling everything from system class selection through hydraulic calculations and coordination with sprinkler and fire pump designs.

Opens the Project Desk with your sentence. Our licensed PEs review every brief and reply within one business day.

Standpipe system diagram: riser, hose connections, and fire department connection serving every floor

What’s Included

What standpipe system design includes

DGA provides standpipe system design for commercial, residential, and mixed-use buildings across New York, New Jersey, Pennsylvania, Maryland, Delaware, Washington, Oregon, and Florida. Our licensed Professional Engineers design systems per NFPA 14, from class selection through hydraulic calculations and coordination with the other fire protection trades.

System class selection

Class I, II, or III systems selected based on building height, occupancy, and AHJ requirements.

Hydraulic calculations

Pressure and flow verified at the most remote hose valves, including pressure-regulating valve needs on lower floors.

Hose valve and riser layout

Locations coordinated with stairs, exits, and fire department access.

Combined systems

Standpipes combined with automatic sprinkler systems where permitted, with demand calculations covering both.

Fire pump coordination

Where supply pressure is insufficient, the standpipe design integrates with the fire pump design.

Standpipe flow testing

Witnessed acceptance flow tests and the documentation the AHJ needs to sign off.

When It Applies

When standpipe system design applies

Triggers

When standpipe design applies

  • Mid- & High-Rise Buildings: Buildings with a floor more than 30 feet above the lowest level of fire department vehicle access, where the IBC requires standpipes.
  • Large-Footprint & Special Occupancies: Warehouses, covered malls, arenas, and stages where hose travel distance or the occupancy triggers standpipes.
  • System Classification: Determining whether a Class I, II, or III and a wet, dry, or automatic system is required before permit.
  • Additions & Adaptive Reuse: Vertical additions and renovations that need riser extensions, pump upgrades, or new cross-connections.

What We Deliver

Standpipe engineering & hydraulics

  • NFPA 14 Hydraulic Calculations: 500 gpm at the most remote standpipe plus 250 gpm per additional standpipe, at 100 psi residual at the topmost outlet.
  • Pressure-Regulating Valve (PRV) Schedules: Static and residual pressure calculations to size and set PRVs where outlet pressures exceed NFPA 14 limits.
  • PE-Stamped Riser Diagrams: Riser schematics, cross-connections, isolation and drain valves, and fire pump room piping.
  • FDC & AHJ Coordination: Fire department connection location, piping and check valve arrangement, and plan review responses.

Process

The design process

01

Determine requirements

Building height, occupancy, and jurisdiction define the system class.

02

Lay out and calculate

Riser locations, hose valve placement, and full hydraulic calculations.

03

Coordinate

Coordination with sprinkler, fire pump, and architectural trades.

04

Document and support

Permit drawings plus plan review and construction support.

FAQ

Frequently asked questions

What is the difference between Class I, II, and III standpipes?

Class I is for fire department use with 2-1/2-inch hose connections, Class II provides 1-1/2-inch hose stations for trained personnel or the fire department during initial response, and Class III combines both. The building’s height and occupancy determine which class is required.

Do standpipes always require a fire pump?

Not always. Whether a pump is required depends on whether the water supply can deliver the required pressures at the highest hose valve. Tall buildings usually need one, and the firm’s hydraulic calculations provide the definitive answer.

Can standpipes share piping with the sprinkler system?

Yes. Combined systems are permitted under NFPA 14 and NFPA 13 in many cases, which can reduce cost. The hydraulic calculations must account for both demands.

Which states are you licensed in?

New York, New Jersey, Pennsylvania, Maryland, Delaware, Washington, Oregon, and Florida. Each project is sealed by a Professional Engineer licensed in the state where it is located.

When does a building need a standpipe?

The building code sets the trigger, usually based on how high the top floor is above fire department vehicle access. The code each state enforces, and New York City’s code, can differ, so DGA confirms the trigger before design starts.

Related Services

Related services

Construction supervisor directing work on a modern building site

Fire pump design

Fire pump selection, sizing, and system design for reliable water supply.

Learn More

Engineers reviewing fire protection blueprints in an industrial plant

Fire protection engineering design

Integrated sprinkler, alarm, and hydraulic design for new and existing buildings.

Learn More

Fire sprinkler pipe system under inspection at a worksite

Sprinkler shop drawings & hydraulic calculations

Sprinkler shop drawings and hydraulic calculations for installation.

Learn More

Quick inquiry

Ready when you are.

Your name, a way to reach you, and where the project is. A licensed PE replies within one business day. Every inquiry is confidential.

Prefer to describe it first? Open the Project Desk