Smoke Control System Design & Testing

In a fire, smoke is often the greater threat to life safety than flame. DGA Consulting designs smoke control systems, from stairwell pressurization to atrium exhaust, that keep egress routes tenable and support firefighting operations.

Smoke control diagram: keeping the smoke layer above people in an atrium, per IBC Section 909 and NFPA 92

What’s included

What smoke control system design and testing includes

DGA Consulting designs and tests smoke control systems for commercial, institutional, and high-rise residential buildings across New York, New Jersey, and Pennsylvania. The firm’s engineers handle the full scope: design rationale, system design, sequence of operations, and acceptance testing support.

Stairwell pressurization

Design of pressurized exit stairs serving high-rise and underground occupancies.

Atrium and large-volume smoke exhaust

Exhaust system design for atriums, malls, and warehouses with high ceilings.

Zoned smoke control

Floor-by-floor smoke management strategies for complex buildings.

Design rationale and sequence of operations

Written documentation of the smoke control concept for permit and AHJ review, plus a detailed matrix defining system response to every alarm scenario.

Acceptance testing support

Test criteria development and field support through commissioning.

When it applies

When smoke control system design and testing applies

When you need it

  • High-rise buildings with pressurized stair requirements.
  • Atrium and large-volume spaces that trigger smoke exhaust requirements.
  • Underground occupancies needing smoke management strategies.
  • Assembly and healthcare uses with IBC and NFPA 92 smoke control triggers.
Rooftop smoke exhaust ductwork and vents

Process

The design and testing process

01

Define the strategy

Building geometry, occupancy, and code requirements determine the smoke control approach.

02

Design

System layout, equipment selection, and the sequence of operations, coordinated with the mechanical engineer.

03

Document

Design rationale report, drawings, and specifications for permit.

04

Test

Acceptance testing criteria and field support through commissioning.

FAQ

Frequently asked questions

What’s the difference between smoke control and smoke detection?

Detection systems find the fire; smoke control systems manage where the smoke goes. The two systems are designed to work together, with detection initiating the smoke control sequence.

Does the firm coordinate with the mechanical engineer?

Yes. Smoke control is inherently multidisciplinary. The firm defines the fire protection strategy and sequence of operations and coordinates closely with the mechanical design team on equipment and ductwork.

Can the firm test an existing smoke control system?

Yes. The firm develops test protocols and supports periodic testing of existing installations.

Which states are you licensed in?

The firm’s engineers are licensed fire protection engineers in New York, New Jersey, and Pennsylvania.

Related services

Related services

Construction supervisor directing work on a modern building site

Fire Modeling & Performance-Based Design

Computational fire modeling to support performance-based design.

Learn more

Engineers reviewing fire protection blueprints in an industrial plant

Commissioning & Integrated System Testing

Third-party commissioning and integrated testing of fire protection systems.

Learn more

Fire sprinkler pipe system under inspection at a worksite

Fire Alarm System Design

Fire alarm and detection system design for new and existing buildings.

Learn more

For smoke control system design and testing, contact DGA Consulting. The firm responds within one business day.